Engineering
Engineering, 08.11.2019 05:31, naomifelixwoo

Anatural-circulation pillow-block bearing with lyd 5 1 has a journal diameter d of 2.500 in with a unilateral tolerance of 20.001 in. the bushing bore diameter b is 2.504 in with a unilateral tolerance of 0.004 in. the shaft runs at an angular speed of 1120 rev/min; the bearing uses sae grade 20 oil and carries a steady load of 300 lbf in shaft-stirred air at 70°f with a 5 1. the lateral area of the pillow-block housing is 60 in2 . perform a design assessment using minimum radial clearance for a load of 600 lbf and 300 lbf. use trumpler’s criteria.

answer
Answers: 3
Get

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:10, Candi9697
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
image
Engineering, 04.07.2019 18:10, katelynn73
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
Do you know the correct answer?
Anatural-circulation pillow-block bearing with lyd 5 1 has a journal diameter d of 2.500 in with a u...

Questions in other subjects:

Konu
Health, 05.10.2019 05:30
Konu
Mathematics, 05.10.2019 05:30
Total solved problems on the site: 10181678